Lithium Battery Smoke+Carbon Monoxide Alarm JKD-513COM

Lithium Battery Smoke+Carbon Monoxide Alarm JKD-513COM

  • 3V Lithium battery operated
  • High reliable infrad sensor&electrochemical sensor
  • New morden style design&moulding
  • TWO in ONE alarms
  • EN50291&EN14604 certificated
  • Alarm memory function
  • High definition LCD display show PPM no.

Product Categories

Need consultation?

Share your idea, We’ll find solution for you within 24 hours

CO+Smoke Alarm JKD-513COM Introduction

This JKD-513COM is very popular in market and they are very stable in working situation during past few years testing by market.

CO+Smoke,CO only,Smoke only,All style we can customize for you.

The product is a smart carbon monoxide and smoke combo detector,adopts microprocessor control.the electrochemical carbon monoxide sensor is stable and reliable with low current consumption and small sensitivity drift.

Mostly used in the place of carbon monoxide gas leakage and fire place, well guarantee personal safety.

User Instruction

1.FIRST START

Insert 3 pieces 1.5VAA battery to the detector, the buzzer will make a sound”di”, the detector starting preheating, It will display 2 minutes counting when the detector is in starting-up.

2.BUTTON

Press”TEST” button,LCD display “CO Oppm”,and then smoke “0.00db/m”, LED flickering and the detector will sound continuous alarm.

3.PEAK RECOBD

Press”TEST”button.check alarm concentration long ress”TEST button for more than 10 seconds again for dean up.

4.INDICATION LIGHT

Under the normal standby situation, the green ligh lashes one time at every 35 seconds.

5.LOWBATTERY WARNING

When the battery capacity is low, the red light flashesone time at every 10 seconds, and the LCD display”Lb”.

6.ALARM

CO:EN50291

 

Standard: EN50291-1:2018

50ppm, alarm within 60-90 minutes
100ppm, alarm within 10-40 minutes
300ppm, alarm within 3 minutes
over 300ppm,alarm immediately

the buzzer will make sound “di”four times at every 5 seconds, the red light flashes, and continue alarm. please immediately turn off the valve, open the windows and doors, then call your emergency service.

Smoke:EN14604
If there is a fire, when the unit detect the smoke concentration over than 0.1%db/m,it will alarming the blue light flash rapidly and the buzzer continue alarm.

Working voltage: DC4.5V (3pcs AA battery)
Standby current:  <20uA
Alarm currect <50mA
Warming time:  2 minutes
Pressure: 86kPA~106kPA
Inspection gas: smoke;carbon monoxide
Detecting:  Smoke over than 0.1%db/m

CO alarm over 200×10-6

User environment: temperature: -10°C~55°C ;Relative humidity:<95% without crystallization;
Alarm type :  sound and light alarming
Alarming volume: >80dB (at three meter directly in front)
Sensor:  infrad sensor&electrochemical sensor
Weight: about 180g
Dimensions: 104*104*39mm
Shell protection grade:  IP30
 

 

Certificates

EN50291
EN14604
IEC62321-1:2013
EN55014-1:2017

 

How to maintance your detectors?

First to use

This machine has been calibrated before leaving the factory. You only need to clean the housing of the detector frequently during use to ensure that the hole in the front of the detector is not blocked by dirt or dust .

Basically, no other maintenance is required. When cleaning the detector housing, please use a clean soft brush or dry flannel to wipe, do not use detergent, bleaching powder or polish.

End of detector life

During the working process of the detector, a self-checking test is carried out every minute.
Under normal use, the detector can operate for 5 years. When the detector sends out an end-of-life signal (the buzzer beeps once every minute), the detector must be replaced. If the detector reaches the end of its life, please follow local regulations for disposal.

WARNING

This product is designed for indoor use only. Please avoid the detector from being exposed to rain or moisture, and avoid dropping the detector. Do not knock, open or modify the detector, otherwise it may cause the product to malfunction.
Covering the detector, improper use or maintenance may reduce or lose the detection function.

What certificates do you have on smoke+CO Alarm?

We have full CE/RoHS certificates asEN50291,related to CE Directive(s) R305/2011,EN14604,EN62368-1:2014+A11:2017,etc

How you make sure smoke+CO alarm’s calibration is set?

We have gas calibrators both for sample and mass production,The calibration team have 5 employees aim to make sure the alarms are set.

What kind of sensor do you apply in smoke+CO alarms?

Most of our carbon monoxide alarm use infrad&electrochemical sensors,3~5 years life,5~7 years life and 10 years life.

What language you can offer for VOICE alarm?

Standard language is English,We have experience make Japanese,Spanish,Germany,Russia,etc.You can offer us some audio data if you have.

Can I make my own logo and color box?

Sure,OEM/ODM are welcome but need MOQ at 500pcs,All cost are pree include logo printing,color box designning or even language customization.

What is your lead time?

Sample can be ready in 3 days.Mass production need one week when quantity lower 2000pcs,we need add more three days if you have OEM requirement.

What if I need return the goods,Who pay the shipping fee?

All our products enjoy 12 months’ quality warranty.In this period, We here ensure you that goods can be returned and we will cover the shipping fee if the alarms not working because of the less in quality.

 

coming soon

Quality, credit, service - we promise you always!

Related Products

Get A Quote

Quality, credit, service – we promise you always!

We respect your confidentiality and all information are protected.